Poolex O'Spa 3, 5 or 7 kW Heat Pump Chiller image 1

Poolex O'Spa 3, 5 or 7 kW Heat Pump Chiller

Heat pump that cools a cold tub to 2 °C and heats a hot tub to 40 °C. Comes in 3, 5 and 7 kW.

Choose a size

Pick one to continue.

Choose a pump

Pick one to continue.

Cools your cold tub to 2 °C. Heats your hot tub to 40 °C.

The Poolex O'Spa heat pump cools or heats your tub water and holds it at the temperature you set. It comes in three sizes: 3, 5 and 7 kW.

Cooling works reliably when the outside air is above 10 °C. In colder air, the pressure inside the unit drops and cooling power goes down.

It has no pump of its own. It needs a circulation pump that moves at least 1.4 m³/h (3 kW), 2.15 m³/h (5 kW) or 3 m³/h (7 kW). We use the Filter Max with all three.

Key Features

  • Cools and heats. Three modes: cooling, heating and auto.
  • Water range. In cooling mode you set the water anywhere from 2 to 30 °C. In heating mode, from 10 to 40 °C.
  • How fast it heats. In normal conditions, about 1 to 2 °C per hour. It goes faster in a small, covered tub and in warm air, and slower in a big tub or in cold air.
  • Titanium heat exchanger. Resists corrosion.
  • Relay in the box. With it, the unit can turn an electric heater on and off by itself. It doesn't plug in: an electrician wires it in.
  • Control. Use the display on the unit or the Poolex app. The unit connects only to 2.4 GHz Wi-Fi.

Plug and Play

  • Factory fitting, paid separately. Buy it with one of our tubs and our factory fits it: the inlet and outlet pipes on the tub, then a test run of the whole system before it ships. Custom wishes cost extra.
  • We disconnect the unit from the tub for delivery. You connect it again before you fill the tub.
  • Plug the unit into an earthed outdoor socket within 5 m. The Filter Max needs a second one. Keep both sheltered from rain and splashes.
  • The plug has a built-in safety switch (RCD) and a 5 m cord.
  • The unit stands on its own next to the tub, on firm, level ground. A concrete slab is best.

Before You Buy

  • A circulation pump. At least 1.4 m³/h for the 3 kW, 2.15 m³/h for the 5 kW and 3 m³/h for the 7 kW. The unit has none. We use the Filter Max with it.
  • Space around the unit. At least 1.5 m free in front. At least 30 cm free at the sides and back. Nothing on top.
  • Heating in cold weather. Below 10 °C outside it keeps warm water warm, but heats cold water up only slowly on its own. For faster heating, add an electric heater. The relay in the box switches it on. For safety, an electrician must wire the heater to the relay.
  • Water pH between 6.9 and 8.0. This protects the unit.
  • Winter. If it runs through a frost, keep the water moving all the time. Water that stops can freeze and crack the unit, the pump and the hoses. If you drain the tub for winter, take the unit off the tub and store it dry.
  • Insulation and a lid help. An insulated tub, insulated pipes and a cover help the unit work at its best. See our PUR tub insulation and our lids.

Refrigerant (F-gas Information)

EU law asks us to show this for units with this kind of refrigerant.

  • Contains fluorinated greenhouse gases.
  • Gas: R32 (HFC-32)
  • Amount:
    • 3 kW: 0.24 kg, equal to 0.16 t CO2 equivalent
    • 5 kW: 0.40 kg, equal to 0.27 t CO2 equivalent
    • 7 kW: 0.45 kg, equal to 0.30 t CO2 equivalent
  • Global warming potential (GWP): 675
Downloads
User manual (PDF, May 2025, 25 MB)
Newest version (on the maker's website)

Technical Specifications

3 kW5 kW7 kW
Cooling capacity (air 15 °C, water 5 °C)1.46 kW2.14 kW3.15 kW
Cooling capacity (air 35 °C, water 27 °C)2.03 kW2.75 kW4.10 kW
Heating capacity (air 26 °C, water 26 °C)3.26 kW, COP 5.355.06 kW, COP 5.707.10 kW, COP 5.60
Water flow1.40 m³/h2.15 m³/h3.00 m³/h
Max power1.40 kW, 6.2 A1.70 kW, 7.6 A2.50 kW, 12.0 A
RefrigerantR32 (HFC-32), 0.24 kgR32 (HFC-32), 0.40 kgR32 (HFC-32), 0.45 kg
Sound level48 dB(A) at 1 m, under 30 dB(A) at 10 m48 dB(A) at 1 m, under 30 dB(A) at 10 m50 dB(A) at 1 m, under 35 dB(A) at 10 m
Dimensions400 × 440 × 382 mm400 × 440 × 382 mm510 × 490 × 430 mm
Net weight27 kg33 kg42 kg

All three sizes:

  • Type: Heat pump chiller. No circulation pump.
  • Modes: Cooling, heating, auto
  • Water temperature range, cooling: 2-30 °C
  • Water temperature range, heating: 10-40 °C
  • Air temperature range, cooling: 7 to 40 °C
  • Air temperature range, heating: -7 to 43 °C
  • Power supply: Single phase, 220-240 V ~50 Hz
  • Compressor: Rotary
  • Heat exchanger: Titanium
  • Connections: PVC 32 mm
  • Protection rating: IPX4
  • Control: Digital display on the unit, Wi-Fi and Poolex app (2.4 GHz only)
  • CE marking: The unit carries its maker's CE marking.

What's Included

  • 2 × 1" to 32/38 mm connections
  • 2 stainless steel hose clamps
  • Control relay for a heater
  • 4 vibration pads (fitted under the unit)
  • Manual